Galvanized Class B Hardboard Fire 813 X 2032
SKU: BHBG8

Class B 2-Hour Fire Door 813 × 2032mm | Galvanized Cladding

Price
Regular price R 8,37100
Regular price Sale price R 8,37100
Save
/
inc vat. Shipping calculated at checkout.

877 mm

2064 mm

230 mm

  • Lead time 14 - 21 Days

  • Nationwide delivery

  • Secure payments

  • Visa
  • Mastercard
  • American Express
  • Payflex
  • mobicred
  • Zapper

Pairs well with


Description

Class B 2-Hour Fire Door 813 × 2032mm | Galvanized Cladding

This pre-hung Class B fire door assembly is designed for South African commercial applications where fire resistance, weather exposure and compliant installation all matter. The exterior face has galvanized steel cladding for weather and corrosion resistance, while the hardboard interior skin is supplied unpainted and ready for painting.

The door is pre-hung in a double-rebated mild steel frame with stainless steel hinges. The tested assembly achieved 120 minutes of stability and integrity, with 60 minutes of insulation, when installed in accordance with the certified configuration.

Key features

  • Class B fire rating: 120 minutes (2 hours)
  • Galvanized steel cladding on the exterior face
  • Hardboard interior skin, ready for painting
  • Pre-hung in a double-rebated mild steel frame
  • Stainless steel hinges
  • Two concealed edges for a clean finished appearance
  • 1.6mm mild steel frame with 25mm × 50mm rebates
  • Frame suitable for a 230mm wall
  • Red oxide primer applied to the frame
  • Available with 22mm screed or no-screed finish
  • Compatible with conventional drywall fixing
  • Supplied unpainted, ready for the specified finish
  • Custom sizes available on request

Specifications

  • Door size: 813mm wide × 2032mm high × 50mm thick
  • Overall frame size: 2064mm high × 877mm wide × 230mm deep
  • Fire rating: SANS 1253 Class B, 120 minutes
  • Exterior face: Galvanized steel cladding
  • Interior skin: Hardboard, suitable for painting
  • Frame: 1.6mm mild steel, red oxide primed
  • Hinges: Stainless steel
  • Wall thickness: Suitable for 230mm walls
  • Lead time: 14–21 days

Opening direction and door handing

The certified assembly supports two project configurations. For outward-opening fire-escape use, the tested configuration includes a certified 3-point panic push-bar. For inward-opening exit use, the tested configuration includes an approved lockset. Confirm the required configuration and handing before ordering.

  • Left hand: Hinges are on the left when standing on the hinged side of the door
  • Right hand: Hinges are on the right when standing on the hinged side of the door

Custom sizes

Non-standard door sizes are available on request. Contact info@doorsdirect.co.za or WhatsApp Doors Direct on 087 012 5283 to discuss project requirements and custom-size lead times.

Certification and fire-test details

This fire-door assembly was independently tested and classified in accordance with South African standards:

  • Test authority: FIRELAB cc, Pretoria
  • Classification standard: SANS 1253
  • Test method: SANS 10177-2
  • Classification achieved: SANS 1253 Class B, 120-minute fire-door assembly
  • Certificate reference: FTC 25/099, valid until December 2030
  • Full test report: FTC 20/199, available on request

Verified fire performance: Stability (R) 120 minutes, Integrity (E) 120 minutes and Insulation (I) 60 minutes. The tested assembly achieved E120, exceeding the minimum E60 integrity requirement for Class B doors under SANS 1253.

The tested assembly used a single-leaf door with a symmetric MgO composite core and Meranti hardwood edges, mounted in a 25 × 50mm steel frame with three hinges and a door closer. It was tested as an outward-opening fire-escape door with a certified 3-point panic push-bar and as an inward-opening exit door with a standard lockset. The Class B certification applies when installed in accordance with the relevant tested configuration.

Typical applications

Suitable where a 120-minute fire-rated door is required under South African building regulations, including:

  • Stairwells and lift-lobby shafts
  • Major fire-break walls in commercial, industrial or public buildings
  • High-risk fire-compartment boundaries
  • Main escape routes in multi-storey developments
  • Areas requiring SANS 1253 Class B compliance

Installation note: The Class B rating is valid only when the door is installed as a complete assembly equivalent to the tested configuration, including the matching steel frame, three hinges, door closer and the appropriate certified panic push-bar or approved lockset.

Frequently asked questions

What is a Class B fire door?

A Class B fire door provides 120 minutes (2 hours) of fire resistance. In South Africa, Class B fire doors are classified to SANS 1253 and tested to SANS 10177-2. This assembly achieved R120/E120/I60: 120 minutes of structural stability and flame integrity, and 60 minutes of thermal insulation.

What does R120/E120/I60 mean?

Stability (R) means the door remains structurally intact for 120 minutes. Integrity (E) means flames or hot gases do not pass through for 120 minutes. Insulation (I) means the unexposed face remains within the required temperature limits for 60 minutes.

Where are Class B fire doors required?

Class B fire doors are typically used in stairwells, lift lobbies, corridors and fire compartments in commercial buildings, hotels, hospitals and multi-storey residential developments. Requirements depend on SANS 10400-T and the project fire strategy.

Do these fire doors come pre-hung?

Yes. The fire door is supplied pre-hung in a double-rebated mild steel frame with stainless steel hinges. The complete assembly must be installed in accordance with the tested configuration.

Can this fire door open inward or outward?

Yes, the tested assembly supports both configurations. Outward-opening fire-escape use requires the certified panic push-bar configuration, while inward-opening exit use requires the approved lockset configuration. Confirm the required configuration before ordering.

Can I get a custom size?

Yes. Custom sizes are available on request, with a typical custom-size lead time of 14–21 days. Contact info@doorsdirect.co.za or WhatsApp Doors Direct on 087 012 5283 to discuss your opening dimensions.

What finish options are available?

The exterior face has galvanized steel cladding for weather and corrosion resistance. The hardboard interior skin and red oxide primed frame are supplied unpainted and ready for the specified finish.

Can I get the fire-test certificate?

Yes. Certificate FTC 25/099 from FIRELAB cc, valid until December 2030, and the full FTC 20/199 test report are available on request.

What is the lead time?

The typical lead time is 14–21 days from order confirmation. Nationwide delivery is available across South Africa.

Where can I buy a Class B fire door in South Africa?

This Class B 2-hour fire-rated door with galvanized cladding is available online from Doors Direct with nationwide delivery across South Africa, including Johannesburg, Cape Town, Durban, Pretoria, Gqeberha, Bloemfontein, towns, rural areas and surrounding regions.

Material

Wood

Shipping information

Delivery Information

At Doors Direct, we strive to make the delivery of your quality doors a seamless and convenient experience.

Nationwide Delivery:

Based in Durban, we extend our reach to bring our premium products directly to your doorstep anywhere in South Africa. Our efficient overnight transport ensures that you receive your order promptly.

Cost-Effective Options:

With a diverse range of transport service providers, we have the flexibility to secure competitive quotes, especially for bulk orders. Feel free to contact our office at 031 012 5033 to explore cost-saving options tailored to your needs.

Lead Times and Timely Delivery:

Our commitment to transparency is reflected in the lead times displayed on our website for made-to-order products. Once your order is dispatched, anticipate delivery within 24 – 48 hours, allowing you to enjoy your new doors without unnecessary delays.

Quality Assurance:

Doors Direct takes pride in delivering products that are undamaged and in excellent working order. While we make every effort to maintain the integrity of your purchase, we recognize that, on rare occasions, products may incur damage during shipping.

Damaged Products:

In the unfortunate event that your product arrives damaged, we have a straightforward solution. At our discretion, Doors Direct will either repair or replace damaged items. To facilitate this process, please ensure that the waybill is endorsed with details of the damages. For more details, refer to our comprehensive guarantee policy and terms and conditions at Guarantee Policy and Terms & Conditions.

Contact Us:

Have questions or need assistance? Contact our head office at info@doorsdirect.co.za or 087 012 5286. We are here to ensure your satisfaction at every step of the journey.

Thank you for choosing Doors Direct – Elevating your door-buying experience with quality, efficiency, and reliability.

Ask a question

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Related products